Engeneering
• Design, development and conception of new equipment and machinery in Solidworks 3D • Layout of the electrical and compressed air components for equipment • Control cabinet construction • Installation and commissioning of the planned equipment • Programming the equipment software and operator interface of the equipment • Training courses for operating and service staff for the equipment • Maintenance of the equipment • CNC parts production for machine manufacturing • Laser writing, laser marking or laser engraving of components • Preperation of the relevant documents for the equipment • Creation of the relevant inspection certificates (e. g. VDE, CE conformity) • Generation of the required circuit diagrams (electrical, compressed air etc.) • Quality assurance per the DIN EN ISO 9001 standard • Creation of the risk analysis and the assessment of risks for the equipment

Engineering Tool LASAL
With the Engineering Platform LASAL, you are provided with an integrated and user-friendly tool set for all phases of machine design: project development, control programming (CLASS) visualization (SCREEN and web-based with LASAL VISUDesigner), motion control (MOTION), Safety (SAFETY), simulation, initial start-up, service, diagnostics and remote maintenance (SERVICE) of the machine and system in the field. LASAL combines object-oriented programming (IEC 61131-3 standard) with graphic representation and makes mechatronic engineering possible: Real machine components can be represented by software objects. With the extensive LASAL Libraries, you can get quickly and easily to your application software. In the approach of Industry 4.0 and Smart Factories, the LASAL Machine Manager has the data flow for distributed intelligences in multi-CPU concepts firmly under control. In addition, the LASAL OPC UA Server enables manufacturer- and platform-independent data exchange directly on the controller.

ENUX Serie
THE ENCLOSURE FOR AUTOMATION Conserving and improving environmental resources over the long term, investing in innovative production processes over the long term and offering high quality solutions: this is our corporate philosophy, of which E NUX, ETA's top-of-the-range modular enclosure system, is a tangible symbol. Innovation takes shape on several levels: research into efficiency and environmental protection, investment in technologically advanced systems and energy-saving manufacturing processes, choice of latest generation materials with high yield strength and high mechanical properties. The E NUX enclosure system is a combination of the most advanced technical and quality features to enhance the functionality, robustness and versatility of the enclosure.

EPA AF-BCR
EPA's AF-BCR - the absorption filter in order to avoid motor bearing damages ✓ Absorption tunnel® 3 x 11 mm, 3 x 18 mm or 3 x 44 mm ✓ Reduces maintenance and downtimes ✓ Easy to retrofit ✓ Flexibly combinable with other RFI filters

EPA DiffDi®
EPA's DiffDi®, a system for differential current diagnosis, makes leakage currents visible and thus assessable. ✓ Differential current diagnosis on frequency-controlled drives ✓ Investigation of high-frequency currents and their effects on the motor (motor damage due to bearing currents)

EPA LEAKCOMP® HP
EPA's LEAKCOMP® HP is used for leakage current compensation in power grids with servo drives and frequency inverters. ✓ Compensation of operational leakage currents up to 500mA (RMS) ✓ Increases the safety for devices on a RCD ✓ Use of RCDs with a residual current of 30mA or higher according to DIN VDE 0100-530 is possible ✓ Compatible with type B and B+ RCDs

EPA LEAKWATCH
EPA's LEAKWATCH leakage current measurement and analysis system makes leakage currents visible and thus assessable. ✓ Leakage current displaying in the Fourier analysis and as RMS value ✓ Leakage current evaluation in relation to the tripping characteristic of all market standard type B / B+ residual current devices ✓ Recording of switch-on / -off current spikes

EPA NF-1ph-GSC
EPA's NF-4-GSC – Universal compact filters for noisy applications an devices Whether it’s the NF-1ph-GSC, NF-1ph-FSE, or NF-1ph-GSG, there’s a compact filter to suit every performance requirement: as performance requirements decrease, the size of the filter can be reduced proportionally. ✓ High differential and common mode attenuation ✓ Current ratings from 1 A up to 30 A ✓ Single-phase, single-stage filter

EPA NF-1ph-GSG
EPA's NF-1ph-GSG – Universal compact filters for noisy applications Whether it’s the NF-1ph-GSC, NF-1ph-FSE, or NF-1ph-GSG, there’s a compact filter to suit every performance requirement: as performance requirements decrease, the size of the filter can be reduced proportionally. ✓ Very high differential and common mode attenuation ✓ Current ratings from 1 A up to 30 A ✓ Single-phase, two-stage filter

EPA NF-4-GTR
EPA's NF-4-GTR – High performance mains RFI filters for machinery Two-stage enhancement of the EPA NF-4-FTN (single-stage RFI filter) for improved performance ✓ Low leakage current and very high attenuation ✓ Compact case style ✓ For current ratings from 8 A up to 200 A ✓ Three-phase with neutral conductor, two-stage

EPA NF-CF
EPA's NF-CF – Compact filters for frequency inverters and power drive systems Double deck design: high performance with a smaller footprint – reduced length with greater depth ✓ Very small dimensions (bookstyle) ✓ Very good attenuation properties ✓ Current ratings from 10 A up to 230 A

EPA NF-DAR / NF-KC-DAR
EPA's NF-DAR / NF-KC-DAR - the Leakage current reduction filters with and without internal EMC filter ✓ For suppression of unwanted leakage currents ≥ 2 kHz ✓ Increases the safety for devices with an RCD ✓ EMC improvement ✓ For nominal currents up to 800 A

EPA PECON+®
EPA's PECON+® is used for protective conductor monitoring for single-phase and three-phase power grids. ✓ For use of frequency inverters and servo drives ✓ The 3.5 mA limit may be exceeded according to the following standards: • DIN EN IEC 62477-1 / VDE 0558-477-1 (AC 3.5 mA limit for electronic equipment) • DIN EN 61800-5-1 / VDE 0160-105 (AC 3.5 mA limit for power drive systems) • DIN EN 60204-1 / VDE 0113 (AC 10 mA limit for machines) ✓ For networks with rated voltages of 230 VAC up to 400 VAC with or without neutral

EPA PreLEAK® TECHNOLOGY - NF-KC-LKY
EPA's NF-KC-LKY - Line filters with PreLEAK® TECHNOLOGY for a safe operation on the RCD ✓ Unique technology worldwide ✓ No faulty RCD trippings while switching machines and systems on or off ✓ No faulty RCD trippings while connecting and disconnecting the CEE plug ✓ Very good attenuation properties

EPA RCCB type B / B+
EPA's RCCB Type B / B+ from EPA - the AC/DC-sensitive residual current circuit breaker with special characteristic for drive technology ✓ Tripping frequency response for the protection of systems with frequency inverters ✓ Rated residual current 30 mA for contact protection according to the selection recommendations of DIN VDE 0100-530 ✓ Rated residual current 0.3 A for fire protection according to the guidelines of VDS 3501 ✓ Safety through detection of smooth DC residual currents and AC residual currents up to 150 kHz